Accelerometer Products Accelerometers

Accelerometer Product Tree

Compare Honeywell’s Measurement, Control and Navigation Accelerometers


MEASUREMENT QA650 QA700 QA750
Input Range [g] ±30 ±30 ±30
Bias [mg] < 15 < 8 <8
  - 1 year Stability [µg] < 700 < 600 < 500
  - Temperature Sensitivity [µg/ºC] < 100 < 70 <60
Scale Factor 1.20 to 1.40 1.23 to 1.43 1.20 to 1.46
  - 1 year Stability [ppm] < 700 < 600 < 500
  - Temperature Sensitivity  [ppm/ºC] < 200 < 200 < 190
Vibration Rectification [µg/g 2 rms] < 100 (50-500 Hz) < 50 (50-200 Hz)
< 100 (200-750 Hz)
< 150 (750-2000 Hz)
< 60 (50-500 Hz)
< 200 (500-2000 Hz)
Bandwidth [Hz] > 300 > 300 > 300
Intrinsic Noise [µg-rms] < 3000 (0-10,000 Hz) < 7 (0-10 Hz)
< 70 (10-500 Hz)
< 1500 (500-10,000 Hz)
< 7 (0-10 Hz)
< 70 (10-500 Hz)
< 1500 (500-10,000 Hz)
- 0-10 Hz
- 10-500 Hz
- 500 - 10,000 Hz
 

 

CONTROL

QA1400-011

QA1500-010

Input Range [g] ±60 ±90
Bias [mg] <5 <10
  - 1 year Stability [µg] <1000 < 1500
  - Temperature Sensitivity [µg/ºC] < 90 < 100
Scale Factor 1.20 to 1.40 .81 to .99
  - 1 year Stability [ppm] < 500 < 1500
  - Temperature Sensitivity  [ppm/ºC] < 180 < 200
Vibration Rectification [µg/g 2 rms] < 60 (50-500 Hz)
< 20 (50-500 Hz)
< 150 (500-2000 Hz) < 70 (500-2000 Hz)
Bandwidth [Hz]   > 1
Intrinsic Noise [µg-rms]    
- 0-10 Hz < 7 < 10
- 10-500 Hz <70 < 100
- 500-10,000 < 1500 < 4000

 

NAVIGATION QA2000-010 QA2000-020 QA2000-030 QA3000-010 QA3000-020 QA3000-030
Input Range [g] ±60 ±60 ±60 ±60 ±60 ±60
Bias [mg] < 4 < 4 < 4 < 4 < 4 < 4
  - 1 year Stability [µg] < 350 < 220 < 160 < 125 < 80 < 40
  - Temperature Sensitivity [µg/ºC] < 30 < 30 < 30 < 25 < 15 < 15
Scale Factor 1.20 to 1.46 1.20 to 1.46 1.20 to 1.46 1.20 to 1.46 1.20 to 1.46 1.20 to 1.46
  - 1 year Stability [ppm] < 390 < 350 < 310 < 250 < 160 < 80
  - Temperature Sensitivity  [ppm/ºC] < 180 < 180 < 180 < 120 < 120 < 120
Vibration Rectification [µg/g 2 rms] < 40 (500-500 Hz) < 40 (50-500 Hz) < 20 (50-500 Hz) < 20 (50-500 Hz) < 15 (50-500 Hz) < 10 (50-500 Hz)
< 150 (500-2000 Hz) < 60 (500-2000 Hz) < 60 (500-2000 Hz) < 60 (500-2000 Hz) < 40 (500-2000 Hz) < 35 (500-2000 Hz)
Bandwidth [Hz] > 300 > 300 > 300 > 300 > 300 > 300

Intrinsic Noise
[µg-rms]

           
- 0-10 Hz < 7 < 7 < 7 < 7 < 7 < 7
- 10-500 Hz < 70 < 70 < 70 < 70 < 70 < 70
-0500-101,000 Hz < 1500 < 1500 < 1500 < 1500 < 1500 < 1500

 

 

Accelerometers exported from the United States must be done in accordance with the Export Administration Regulations (EAR) and/or the International Traffic in Arms Regulations (ITAR) as applicable.